Projects > New Jersey > Morganville - Snow Melting Asphalt Retrofit

Resident in Morganville, New Jersey

Two snow melting systems installed that cover approx. 600 sq. ft.

Snow melting system retrofit into existing asphalt driveway





The lines for the snow melting system are chalked out for the saw cutter - 1200 lin. ft.

Click on images to enlarge



A professional saw cutter cuts 1/4 inch wide and 1 to 1 1/2 inch deep grooves




Backer Rod, a foam filler, is stuffed in the grooves to take up space between the cable and sealant




The Tuff Cable is splice to the Cold Lead, which connects to the Control Units




Half to one inch wide grooves are cut in the garage to run the Cold Lead to the Control Units - Gray concrete sealant is used in the garage to cover the Cold Leads




Two Control Units (17" x 12" x 8" each) control the Snow Melting Systems - 240 V. 30 amp breakers are required to power each zone




An aerial mounted snow switch is used to automatically turn on the snow melting systems when there is moisture in the air and the temperature is near freezing




Blacktop sealant is used to seal the asphalt driveway and gray concrete sealant is used for the sidewalks and in the garage